For specific recommendations, contact Global Services for a technical bulletin for
your model.
To Change the Tap Settings on the Tune Coil:
1. Turn off RF from the generator.
2. Disconnect AC
3. Disconnect RF in (from the RF-GENERATOR).
4. Disconnect RF
5. Remove the top cover, being careful to not damage the plug leading to the fan:
a. Remove the large top cover (with the fan) from the V arioMatch match network
by unscrewing the twelve screws on the cover. Leave the small top and side
covers in place.
b. Disconnect the
6. Using a 7 mm wrench, unscrew the tap from its current position.
Tabs are silver soldered to the coil. The metal interconnect ribbon is attached to
the tab of the selected turn using a threaded bar and two bolts.
7. Move the tap setting to the desired turn on the coil (for examples, see
through
Figure 5-1
of the ribbon to a new position so the ribbon will reach the chosen tap.
57020080-00D
MAINS.
PLASMA/LOAD).
AE VarioMatch
Match Network, VM 1000/1500 Platform
TM
out
(to
plug
leading from top lid to the fan.
1). It is possible that you will also need to move the other end