EPSON Stylus Pro 10000/10000CF/10600
6.
Remove five screws (M4x8) securing Ink Pump ASSY, then remove it.
1
2
3
4
5
6
Installation position of air tubes (6) is shown in the diagram above, but installation in any
position is acceptable.
Figure 4-144. Air tube location
Disassembly & Assembly
Thank You For Using TheServiceManualShop.com
Ink cartridges rear view
6
5
4
3
2
1
Thank You For Using TheServiceManualShop.com
4.3.3.18 Removing the Scale, CR
1.
Remove the R Side Cover as described in 4.3.1.4 "R Side Cover Removal".
(Remove without forgetting H Top Cover.)
2.
Remove the L Side Cover as described in 4.3.1.5 "L Side Cover Removal".
3.
Marking 7 place of the Scale, CR hold position.
4.
Loosen by 2 rotations the screws at Scale, CR Hold brackets (7 locations, 2 screws
each). Move the Scale, CR Hold brackets to topmost position and temporarily
secure screws.
Scale, CR hold
Screws
5.
Remove the Tention Spring of the left side edge.
Tention spring
Disassembly
Revision D
Figure 4-145.
Scale, CR
Figure 4-146.
175