EPSON Stylus Pro 10000/10000CF/10600
1.2.14 Environmental Conditions
1.2.14.1 Temperature/Humidity
See the following table.
Table 1-9. Environmental Conditions
Condition
Temperature
10~35°C
Operating
(50~95°F)
-20~40°C
Storage
(-4~104°F)
-20~60°C
Transportation
(-4~140°F)
Notes:
1) When storing the printer, make sure the printheads are in the home (capped) position. If
necessary switch power on, wait for the printheads to move to the home position, and then
switch power off.
2) Before transporting the printer, remove the ink cartridges and turn the ink valves screws to
the closed position. Also make sure the printheads are in the home, capped, position. After
transporting the printer, install new ink cartridges.
3) If the temperature drops below -15°C (5°F), the ink in the cartridges and printheads
freezes. The ink thaws completely after three hours at 25°C (77°F).
90
80
70
60
50
Humidity (%)
40
30
20
10
Figure 1-3. Print Temperature and Humidity
Product Description
Thank You For Using TheServiceManualShop.com
Humidity
Notes
• Less than a month at 40°C
20~80%
(104°F)
• Less than 120 hours at 60°C
20~85%
(140°F)
• With no freezing
5-85%
15
10
20
27
30
35
40
Temperature (°C)
Thank You For Using TheServiceManualShop.com
1.2.14.2 Vibration & Shock
See the following table.
Table 1-10. Vibration and Shock
Vibration
Condition
Resistance
Operating
10~55Hz
Storage
10~55Hz
Notes:
* Make sure the printhead is capped during transportation and storage. To cap the printhead,
turn the power on (with ink cartridges installed) and turn the power off when the printheads
are capped.
* To thaw frozen ink in the printer or cartridge, leave the printer out at a temperature of 25°C
(77°F) for approximately three hours.
Specifications
Shock
Resistance
0.15G
1G
maximum 1ms
X/Y/Z directions
0.5G
2G
maximum 2ms
Revision D
Notes
18