EPSON Stylus Pro 10000/10000CF/10600

5.4.8.3 CR + PF Motor

Perform the CR motor and the PF motor simultaneous reliability test.
The CR + PF motor is actuated designated number.
When the reliability number is [-1], reliability is repeated until key is input.
When the reliability number is [-1], the biggest count number is 99,999,999 times
(within 8 column), and the count become 0 in the case that this is exceeded.
Figure 5-95 showing the CR + PF motor reliability test menu sequence.
Speed CW : 240CPS
Enter
Speed CCW : 240CPS
Enter
Feed Amount : 0.1mm
Enter
Life Count : -1
Enter
Count :-10
End : 50
Figure 5-95.
As for the parameter of CW, [240CPS], [300CPS], [400CPS], and [800CPS] are
possible select.
Adjustment
Thank You For Using TheServiceManualShop.com
Adjustable with "Paper Feed +/-" key.
Adjustable with "Paper Feed +/-" key.
Adjustable with "Paper Feed +/-" key
at unit of 0.1mm.
Adjustable with "Paper Feed +/-" key.
Thank You For Using TheServiceManualShop.com
As for the parameter of CCW, [240CPS], [300CPS], [400CPS], and [800CPS] are
possible select.
The maximum value of the paper feed is [100.0mm].
The maximum value of the reliability number designation is [99,999,999 times].
Carriage migration MAX location is 738.06 mm from the starting point location.
Carriage migration MIN location is 111.05 mm from the starting point location.
When the [Pause] key is pushed during the reliability test, the test can be broken.