2-1. INTRODUCTION

2-2. TEST INSTRUMENTS

2-3. LIGHT BULB

103

SECTION 2. MAINTENANCE

This section provides procedures for the checkout and replace-
ment of the various parts used within the cabinet. Before
replacing any parts, refer to the Troubleshooting Section. It will
aid you in determining the cause of the malfunction.
You may use two test instruments to check the electric
components.
1. A continuity light
2. An ohmmeter
When the manual refers to the circuit being closed, the
continuity light will be illuminated or the ohmmeter should
read zero unless otherwise noted.
When the manual refers to the circuit being open, the
continuity light will not illuminate or the ohmmeter will read
1 (one) or infinite resistance.
A continuity tester cannot be used to check coils.
Light bulbs and glass may be hot. Severe burns could
result.
1. Remove the glass panel by carefully pushing up on
back of panel and sliding away from you. The panel
will fall into your hand.
2. Remove the light bulb.