INFORMATION
8.17 Clean and Check Grease Collection on Combi Steamer
8.17.1 Clean Grease Collection System
Note: Verify cooking program has ended.
Clean grease collection system
Test criteria
• Grease collection system has been cleaned.
If no,
Clean the grease collection system.
8.17.2 Function Test Grease Pump
Check grease pump
Test criteria
• Water / grease is pumped into the collection container.
If no,
troubleshoot.
Maintenance only possible to a limited extent.
Detach the grease drain hose from the grease collector.
Connect grease drain hose to existing water hose.
Flush the system for approx. one minute.
Cleaning is complete.
Disconnect the water hose from the grease drain hose.
Detach the grease drain hose from the grease collector.
Mount the backflush fitting on the grease drain hose.
Open the cooking chamber door.
Remove trolley.
Spray water into the cooking chamber with the hand shower for at
least 30 seconds.
Pull up the relay test in the service menu.
Activate relay K13. The grease pump should turn on.
Water / grease is pumped into the collection container = pump
system in order.
Water / grease is not pumped into the collection container = carry
out troubleshooting.
Tap "K13" to exit.
Maintenance instructions
Performing maintenance
Remarks / values
Remarks / values
Yes
No
Yes
No
39