6-7. TEMPERATURE PROBE
REPLACEMENT
(Continued)

6-8. SOLENOID VALVES

May 2012
7. Connect new temperature probe to the connector and fasten
connector onto control panel.
8. Replace control panel and reconnect power to vat.
9. Fill vat by pressing and holding
*MENU* shows in the display. Then once "1.EXPRESS
FILTER" shows in the display, press ► 4 times until "5.FILL
FROM PAN" shows in the display. Press √ button and
"PUMP" "EXIT" shows in the display. Press √ button again,
and oil fills vat. Once vat is full, press X twice to return to
normal operation.
Each vat has a solenoid plumbed-into the oil return lines. They are
normally closed, but open when power is supplied, such as, the con-
trols are filling the vats.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Remove both top and bottom rear panels, or a side panel,
depending upon the location of the solenoid.
Checkout
2. Follow the wires from the solenoid and through the conduit and
then cut the wires. Strip the wires back and take an ohm
reading:
120 Volts - 60Hertz
220-240 Volts -50/60 Hertz
6-9
Model EEG-153, 154
button until *FILTER*
50 Ohms
230 Ohms