IBM Advanced SerialRAID Adapters SA33-3285-02 User Manual page 496

Advanced serialraid adapters
Table of Contents

Advertisement

4. (from step 3)
Do you still have the same SRN?
NO
YES
5. (from step 3 in MAP 2010: START and step 4 in this MAP)
Do you have any other SRN?
NO
YES
6. (from step 4)
Have you have exchanged all the FRUs that were originally reported by the
SRN?
NO
YES
476
User's Guide and Maintenance Information
Notes:
1) Do not run Advanced Diagnostics; otherwise, errors might be
logged on other using systems that share the same loop.
2) If you have just exchanged a disk drive or an SSA adapter, you
might need to run
configuration.
If the original problem was not reported by a device, run diagnostics to
each SSA adapter in the using system.
b. Go to step 4.
Go to step 5.
Go to step 6.
Go to step 7 on page 477.
Go to "Service Request Numbers (SRNs)" on page 411.
Exchange the next FRU that is listed for the SRN.
a. Run diagnostics, in System Verification mode, to all the adapters that
are in this SSA loop.
b. Run diagnostics, in System Verification mode, to all the disk drives that
are in this SSA loop.
c. Run the Certify service aid (see "Certify Disk Service Aid" on page 391)
to all the disk drives that are in this SSA loop.
d. Correct all errors that are reported by the diagnostics.
e. Go to step 7 on page 477.
to restore the device to the system