IBM Advanced SerialRAID Adapters SA33-3285-02 User Manual page 436

Advanced serialraid adapters
Table of Contents

Advertisement

SRN
Problem
40128
Description: A 128 MB SDRAM in the adapter card module has failed.
Action: Exchange the FRUs for new FRUs.
|
|
|
|
42000
Description: Either no SDRAM module is present on the adapter card, or
the POST cannot determine the size of the existing SDRAM module.
Action: Install an SDRAM module of the correct size, or exchange the
existing SDRAM module for a new one of the correct size.
|
|
|
|
42200
Description: Other adapters on the SSA loop are using levels of
microcode that are not compatible.
Action: Install the latest level of adapter microcode onto all the other
adapters on this SSA loop.
42500
Description: The Fast-Write Cache Option Card has failed.
Action:
1. Exchange the cache card for a new one.
2. Switch on power to the using system.
3. If the original cache card contained data that was not moved to a disk
drive, new error codes are produced. Run diagnostics in System
|
Verification mode to the adapter. If an SRN is produced, do the
|
actions for that SRN.
|
|
416
User's Guide and Maintenance Information
Possible Causes
Possible FRUs:
128 MB SDRAM module
(99%) ("Removing an
SDRAM Module of an
Advanced SerialRAID
Adapter" on page 329).
SSA adapter card (1%)
("Removing and Replacing
an Advanced SerialRAID
Adapter" on page 327).
Possible FRUs:
SDRAM module (99%)
("Removing an SDRAM
Module of an Advanced
SerialRAID Adapter" on
page 329).
SSA adapter card (1%)
("Removing and Replacing
an Advanced SerialRAID
Adapter" on page 327).
User or service action.
Possible FRUs:
Fast-Write Cache Option
Card (98%) ("Removing the
Fast-Write Cache Option
Card of an Advanced
SerialRAID Adapter" on
page 332).
SSA adapter card (2%)
("Removing and Replacing
an Advanced SerialRAID
Adapter" on page 327).

Advertisement

Table of Contents
loading

Table of Contents