IBM Advanced SerialRAID Adapters SA33-3285-02 User Manual page 457

Advanced serialraid adapters
Table of Contents

Advertisement

SRN
Problem
504XX Description: The SSA adapter microcode has hung.
Action: Run diagnostics in System Verification mode to the SSA adapter.
If the diagnostics fail, exchange the FRU for a new FRU. If the
|
diagnostics do not fail, go to "Software and Microcode Errors" on
|
page 441.
|
|
:
: :
54050
Description: The adapter bus has been reset.
|
:
Action: Exchange the FRUs for new FRUs.
|
|
|
:
:
:
60000
Description: The SSA adapter is missing from the expected configuration.
|
Action: Verify that the SSA adapter card is installed in the expected slot of
|
the using system.
|
|
If it is in the expected slot, exchange the FRU for a new FRU.
If it is not in the expected slot, give the diag -a command, and answer the
questions that are displayed.
60200
Description: SRNs in this range are not adapter SRNs.
60210
Action: For SRNs in this range, see the documentation for your SSA
enclosure or SSA subsystem.
|
60240
Description: A configuration problem has occurred. A device cannot be
|
configured, for some unknown reason.
|
Action: Go to the START MAP for the enclosure in which the device is
installed. If no problem is found, go to "Software and Microcode Errors" on
page 441.
7XXXX Description: An SSA device is missing from the expected configuration of
the SSA loop.
Action: Go to the service information for the enclosure in which the
missing device should be installed.
Note: In this SRN, an X represents a digit 0 through F.
8XXXX Description: SRNs in this range are used by the SSA enclosure
(subsystem).
Action: Go to the service information for your SSA enclosure.
Note: In this SRN, an X represents a digit 0 through F.
D0000
Description: SRNs in this range are not adapter SRNs.
to
Action: For SRNs in this range, see the documentation for your SSA
D0FFF
enclosure or SSA subsystem.
Chapter 18. SSA Problem Determination Procedures
Possible Causes
Software error.
Possible FRUs:
SSA adapter card (100%)
("Removing and Replacing
an Advanced SerialRAID
Adapter" on page 327).
Possible FRUs:
SSA adapter card (60%)
("Removing and Replacing
an Advanced SerialRAID
Adapter" on page 327).
Using-system board (40%)
(using-system service
information)
Possible FRUs:
SSA adapter card (100%)
("Removing and Replacing
an Advanced SerialRAID
Adapter" on page 327).
Not applicable.
Software error.
SSA loop configuration
problem.
An SSA enclosure diagnostic
has detected a missing disk
drive.
Not applicable.
Not applicable.
437