MAP 2010: START

This MAP is the entry point to the MAPs for the adapter. If you are not familiar with
these MAPs, read "How to Use the MAPs" on page 443 first.
You might have been sent here because:
v The system problem determination procedures sent you here.
v A problem occurred during the installation of a disk subsystem or a disk drive.
v Another MAP sent you here.
v A customer observed a problem that was not detected by the system problem
determination procedures.
Attention:
do not switch off the using system when servicing the SSA loop. Enclosure power
cables and external SSA cables that connect the devices to the using system can be
disconnected while that system is running.
1.
Do you have an SSA subsystem (5-character) SRN?
NO
YES
2. (from step 1)
v If the system diagnostics are available, go to step 3.
v If the system diagnostics are not available, but the stand-alone diagnostics are
v If neither the system diagnostics nor the stand-alone diagnostics are available, go
3. (from step 2)
Run the diagnostics in Problem Determination mode.
Did the diagnostics produce an SRN?
NO
YES
444
User's Guide and Maintenance Information
Unless the using system needs to be switched off for some other reason,
Go to step 2.
Go to "Service Request Numbers (SRNs)" on page 411.
available:
a. Load the stand-alone diagnostics.
b. Go to step 3.
to the problem determination procedures for the enclosure that contains the disk
drives.
Go to step 5 in "MAP 2410: SSA Repair Verification" on page 475.