IBM Advanced SerialRAID Adapters SA33-3285-02 User Manual page 514

Advanced serialraid adapters
Table of Contents

Advertisement

array copy services (continued)
Prepare a Copy option 175
Uncouple a Volume Group, Logical Volumes, or File
Systems Copy option 177
array states, RAID-0 31
Good 31
Offline 31
array states, RAID-1 32
array states, RAID-10 36
Degraded 37
Exposed 36
Good 36
multiple 38
Offline 37
Rebuilding 37
Unknown 38
array states, RAID-5 33
Degraded 33
Exposed 33
read operations while in 33
write operations while in 33
flowchart 35
Good 33
initial rebuilding operation 34
Offline 34
Rebuilding 34
adapter replacement 34
disk drive replacement 34
arrays
adding a disk drive to an SSA RAID array 140
adding a new hot spare pool 83
adding disks to a hot spare pool 86
adding to the configuration 60
canceling all SSA disk drive identifications 129
changing member disks in an SSA RAID array 137
changing or showing the attributes of an SSA RAID
array 135
changing or showing the status of a hot spare
pool 74
changing or showing the use of an SSA disk
drive 144
changing the use of multiple SSA physical
disks 147
creating a hot spare disk drive 72
deleting an old RAID array recorded in an SSA RAID
manager 133
deleting from the configuration 70
identifying and correcting or removing failed disk
drives 91
identifying array candidate disk drives 125
identifying hot spare disk drives 121
identifying rejected array disk drives 123
identifying system disk drives 127
identifying the disk drives in an SSA RAID array 119
installing a replacement disk drive 95
494
User's Guide and Maintenance Information
arrays (continued)
installing and configuring 58
listing all defined SSA RAID arrays 100
listing all SSA RAID arrays that are connected to a
RAID manager 102
listing all supported SSA RAID arrays 101
listing hot spare disk drives 111
listing old RAID arrays recorded in an SSA RAID
manager 131
listing rejected array disk drives 113, 115
listing system disk drives 117
listing the disk drives in an SSA RAID array 109
listing the disks that are in a hot spare pool 80
listing the status of all defined SSA RAID
arrays 104
removing a disk drive from an SSA RAID array 138
removing disks from a hot spare pool 86
showing the disks that are protected by hot
spares 77
swapping members of an SSA RAID array 142
Attention notices
formatting disk drives 389
fragility of disk drives 443
service aids 373
attributes
action
new_member=disk 251
old_member=disk 251
array member disk drives
spare_pool 249
couple action
force=yes/no 252
pool_selection=own/primary/secondary 252
raid_copy=copy 252
disk device driver 270
adapter_a 271
adapter_b 271
connwhere_shad 271
location 271
max_coalesce 271
node_number 270
primary_adapter 271
pvid 271
queue_depth 271
reserve_lock 271
size_in_mb 271
write_queue_mod 272
hot spare disk drives change
spare_pool 249
hot spare pool
minimum_spares 249
ODM, PCI 257
bus_intr_level 257
bus_io_addr 257
bus_mem_start 257

Advertisement

Table of Contents
loading

Table of Contents