Srn 42524; Srn 42525 - IBM Advanced SerialRAID Adapters SA33-3285-02 User Manual

Advanced serialraid adapters
Table of Contents

Advertisement

SRN 42524

If a Fast-Write Cache Option Card fails, or is removed from the adapter, the affected
devices are all those that contain unsynchronized data when the cache card fails, or is
removed. To list these devices, type:
where X is the adapter number. Use the recovery procedure that is described for SRN
42521. You must recover all the devices that are listed.

SRN 42525

If a Fast-Write Cache Option Card fails, or is removed from the adapter, the affected
devices are all those that contain unsynchronized data when the cache card fails, or is
removed. To list these devices, type:
where X is the adapter number. Use the recovery procedure that is described for SRN
42521. You must recover all the devices that are listed.
220
User's Guide and Maintenance Information

Advertisement

Table of Contents
loading

Table of Contents