Identifying And Correcting Or Removing Failed Disk Drives - IBM Advanced SerialRAID Adapters SA33-3285-02 User Manual

Advanced serialraid adapters
Table of Contents

Advertisement

Identifying and Correcting or Removing Failed Disk Drives

When a disk drive fails, the array rejects it. If access to the array is still possible, the
Current Use attribute of the disk drive is changed from Member of an SSA RAID
Array to Rejected. The disk drive is listed in the SMIT menus as a rejected disk drive.
If the disk drive cannot be accessed, however, it cannot be listed as a rejected disk. (A
disk drive cannot be accessed if its Check light is on, or its Power light is off.)
To find rejected disk drives that cannot be accessed, go to "MAP 2010: START" on
page 444 to determine the cause of the failure.
To find rejected disk drives that can be accessed, do the following procedure:
1. For fast path, type
2. A list of adapters is displayed in a window:
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Otherwise:
a. Select List/Identify SSA Physical Disks from the SSA RAID Arrays menu.
b. Select List Rejected Array Disks.
Select the adapter whose rejected disk drives you want to list.
and press Enter.
Chapter 6. Using the RAID Array Configurator
91

Advertisement

Table of Contents
loading