Map 2324: Ssa Raid - IBM Advanced SerialRAID Adapters SA33-3285-02 User Manual

Advanced serialraid adapters
Table of Contents

Advertisement

MAP 2324: SSA RAID

This MAP helps you to solve problems that have occurred in SSA RAID arrays.
Attention:
do not switch off the using system when servicing an SSA link or an enclosure in which
SSA devices are installed. Enclosure power cables and external SSA cables that
connect devices to the using system can be disconnected while that system is running.
Before starting this MAP, ensure that all the disk drives are working correctly:
1. Run diagnostics in Problem Determination mode to identify any disk drive problems
2. Run the Link Verification service aid (see "Link Verification Service Aid" on
3. Correct all those problems before you start this procedure.
Attention:
array, or to change the use of an SSA disk drive. Do not do those steps unless you
have the user's permission.
1. (from steps 3, 28, and 29)
|
|
|
|
2. (from step 1)
|
|
454
User's Guide and Maintenance Information
Unless the using system needs to be switched off for some other reason,
that have occurred.
page 383) to find all power problems, SSA link problems, and SSA disk drives that
have a Failed status.
Some of the steps in this MAP need you to change the configuration of the
You have been sent to this step either from another step in this MAP, or because
you have one of the following Service Request Numbers (SRNs):
46000, 47000, 47500, 49000, 49100, 49500, 49950
Do you have SRN 49500?
NO
a. Run diagnostics in System Verification mode to the SSA adapters.
b. Go to step 2.
YES
No hot spare disk drives are available.
Go to step 21 on page 466.
Did the diagnostics produce SRN 46000, 47000, 47500, 49000, 49100, or
49950?
NO
Go to step 3 on page 455.
YES
Go to step 4 on page 455.