IBM Advanced SerialRAID Adapters SA33-3285-02 User Manual page 455

Advanced serialraid adapters
Table of Contents

Advertisement

SRN
Problem
50002
Description: An SSA adapter DMA error has occurred.
|
Action: Exchange the FRU for a new FRU.
|
|
|
50007
Description: The IOCC detected an internal error.
|
Action: Exchange the FRU for a new FRU.
|
|
|
50008
Description: Unable to read or write the POS registers or PCI
configuration space.
|
|
Action: Exchange the FRU for a new FRU.
|
|
50010
Description: An SSA adapter or device drive protocol error has occurred.
|
Action: Go to "Software and Microcode Errors" on page 441 before
|
exchanging the FRU.
|
|
50012
Description: The SSA adapter microcode has hung.
|
Action: Run diagnostics in System Verification mode to the SSA adapter.
|
|
If the diagnostics fail, exchange the FRU for a new FRU.
|
If the diagnostics do not fail, go to "Software and Microcode Errors" on
page 441 before exchanging the FRU.
50013
Description: The SSA adapter card has failed.
|
Action: Exchange the FRU for a new FRU.
|
|
|
50100
Description: An attempt was made to log an error against a pdisk that is
not available to the using system.
Action: This problem has occurred for one of the following reasons:
v A user has deleted a pdisk from the system configuration. In such an
instance, the hdisk that is using the pdisk continues to operate
normally. If the disk drive tries to log an error, however, this SRN
(50100) is produced. Give the cfgmgr command to return the pdisk to
the system configuration.
v A device has tried to log an error during system configuration. To find
the failing device, run diagnostics to the devices that are connected to
this SSA adapter.
Chapter 18. SSA Problem Determination Procedures
Possible Causes
Possible FRUs:
SSA adapter card (100%)
("Removing and Replacing
an Advanced SerialRAID
Adapter" on page 327).
Possible FRUs:
SSA adapter card (100%)
("Removing and Replacing
an Advanced SerialRAID
Adapter" on page 327).
Possible FRUs:
SSA adapter card (100%)
("Removing and Replacing
an Advanced SerialRAID
Adapter" on page 327).
Possible FRUs:
SSA adapter card (100%)
("Removing and Replacing
an Advanced SerialRAID
Adapter" on page 327).
Possible FRUs:
SSA adapter card (100%)
("Removing and Replacing
an Advanced SerialRAID
Adapter" on page 327).
Possible FRUs:
SSA adapter card (100%)
("Removing and Replacing
an Advanced SerialRAID
Adapter" on page 327).
Disk drive error during system
configuration.
435

Advertisement

Table of Contents
loading