The function of each individual I/O channel is set in the "Channel 0-7" tab. Possible
functions:
● DI
● DO
● Output cam
● Measuring input
All I/O channels can be inverted. A filter time of 1 μs or 125 μs can also be set for digital
inputs and measuring inputs.
The displayed logical address of a channel is only required when symbolic assignments are
not used.
6.12.1.3

Configuration of the CX32-2/CU3xx/TB30/TMxx I/O terminals

The configuration is performed in a similar way as for the onboard I/Os X122/X132 for the
SIMOTION D4x5-2, i.e. the I/Os can be
● BICO-interconnected (use as drive I/O)
● Used by SIMOTION
See also Section Configuration of the D4x5-2 I/Os (terminal X122/X132) (Page 258)
Note
If symbolic assignment is activated retrospectively for a project in which message frames
have already been configured and interconnected, these can be changed together with the
BICO interconnections.
For this reason, make a backup copy of your project before activating the symbolic
assignment.
TB30, TM15 DI/DO and TM31 are especially affected.
See also Section Symbolic assignment / adaptation (Page 153)
6.12.1.4

Configuration of the TMC I/O terminals

The configuration is performed in a similar way as for the onboard I/Os X142 for the
SIMOTION D4x5-2.
The functionality of the I/O channels is configured via HW Config.
For details, see
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 02/2012
SIMOTION Terminal Compact Modules
SIMOTION Terminal Compact Modules
6.12 Configuring drive-related I/Os (with symbolic assignment)
Manual
Commissioning Manual
Commissioning (software)