Example
This illustration below shows an example configuration of a subnet with D4x5-2.
Figure 3-12
3.7.7

Operating the X136 interface as MPI

Applications
The X136 interface can also be operated as an MPI interface instead of a PROFIBUS DP
interface. The typical (default) baud rate is 187.5 Kbaud. A baud rate of up to 12 MBaud can
be set for communication with other CPUs. It should be noted, however, that a rate of
12 MBaud is not supported by all CPUs (e.g. smaller SIMATIC S7 CPUs).
The following list provides examples of when using MPI (multi-point interface) may prove
effective:
● If a PG/PC is being used with an MPI interface
● If an OP/TP only has an MPI interface
● If SIMOTION and SIMATIC CPUs are coupled via XSEND/XRECEIVE
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 02/2012
S
Networking example for a D4x5-2
(newer devices have PROFIBUS or PROFINET interfaces)
3.7 Connecting PROFIBUS/MPI
S
A/M
M
S
Connecting
A
A/S
69