8.2.2.3

Procedure for backing up during operation

Procedure
The advantage of backing up diagnostics data and non-volatile SIMOTION data during
operation is that enhanced diagnostic information via HTML pages and TO alarm information
is available.
Data is backed up:
● With IT DIAG by selecting "Diagnostics > Diagnostics files"; see Section "Backing up
● Via the DIAG button (see the description below).
● Via the Service selector switch (see the description below).
DIAG button (preferred solution)
To back up diagnostics data and non-volatile SIMOTION data via the DIAG button, proceed
as follows:
1. Press the DIAG button.
2. The diagnostic data and non-volatile SIMOTION data is backed up to the CompactFlash
3. Once the backup is complete, switch the D4x5-2 off.
4. Remove the CompactFlash card.
Table 8- 8
Status
Backup in progress
Backup complete
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 02/2012
diagnostics data and non-volatile SIMOTION data via IT DIAG.
Note
In addition to the Service selector switch, SIMOTION D4x5-2 modules also have a DIAG
button.
If the diagnostics data is to be backed up "during operation", simply press the DIAG
button. The DIAG button is therefore preferable to switch position "D" of the Service
selection switch.
The diagnostics data and non-volatile SIMOTION data can be created in STOP, STOPU
and RUN states.
card.
The backup procedure is displayed via the status LEDs as in the table below:
LED displays during backup procedure
8.2 Diagnostic data and non-volatile SIMOTION data
LED displays on the D4x5-2
STOP LED and SU/PF LED flicker yellow
RUN LED flickers green
Diagnostics