Siemens SIMOTION D4 5-2 Series Commissioning And Hardware Installation Manual page 110

Hide thumbs Also See for SIMOTION D4 5-2 Series:
Table of Contents

Advertisement

Commissioning (hardware)
4.4 Fan
Table 4- 10
System variable on the
device
fanbattery of the structfanbattery type (the system variables are of the enumfanbattery type)
.fannecessary
.fanexisting
1)
References
Detailed information on setting up TaskStartInfo(#TSI) can be found in the
SCOUT Basic Functions Function Manual.
110
System variable fannecessary/fanexisting
1)
Value for SIMOTION D4x5-2 is updated dynamically
States
MANDATORY
OPTIONAL
NOT_MANDATORY
SINGLE
REDUNDANT
NOT_EXISTING
Commissioning and Hardware Installation Manual, 02/2012
Description
Fan is required for operation of the device.
.fanexisting can be used to query whether
a fan is available.
Examples: D410-2, D4x5-2
Fan can be used optionally. .fanexisting
can be used to query whether a fan is
available.
Examples: D425, D435
Fan is not required for operation of the
device.
Single fan is available.
Examples: D410-2
Double fan is available.
Examples: D4x5-2
No fan available.
Example: D425 and D435 without optional
fan
SIMOTION
SIMOTION D4x5-2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents