Parameter assignment / addressing
5.5 Configuring an Ethernet subnet
5.5.2

Configuring Ethernet addresses in HW Config

Requirement
For configuration using Industrial Ethernet, SIMOTION D4x5-2 must be provided with an IP
address, the subnet mask, and the router address.
Note
Only one router may be configured.
Procedure
To configure and transfer Ethernet addresses to the D4x5-2, proceed as follows:
1. Open your project.
2. Open HW Config. Double-click the interface to be configured (e.g. X127) to open the
3. On the "General" tab, click the "Properties" button of the Ethernet interface. The
4. Click the "New" button. The "New Industrial Ethernet" subnet dialog is displayed. In this
5. The newly created Ethernet subnet is now displayed under "Subnet" in the "Properties -
6. In this dialog box, enter the required addresses for "IP Address" and "Subnet". Under
7. Confirm this dialog box with "OK".
8. Close the "Properties" dialog by clicking "OK".
9. To configure another Ethernet interface, open the "Properties" dialog box of the other
10. Save and compile the modified hardware configuration.
11. Load the new hardware configuration to the SIMOTION D4x5-2.
136
"Properties" dialog box.
"Properties - Ethernet Interface" dialog is displayed.
dialog box, you can change the name of the new subnet or confirm the default setting
with "OK".
Ethernet Interface" dialog box and must be selected.
"Router", choose whether a router is to be used. If using a router, enter the router
address.
interface and repeat Steps 3 to 7.
Commissioning and Hardware Installation Manual, 02/2012