Service and maintenance
7.2 Replacing modules (spare part scenario)
Procedure for "Installing a component"
1. Install the component and reconnect the supply voltage.
2. Reconnect the DRIVE-CLiQ cable at the same location (port). The cable must have the
3. Activate the affected component or drive object.
Parameters for topology comparator and component replacement
In the expert list, you can use CU parameter p9906 to specify how the electronic rating
plates are compared for all the components of a control unit. The type of comparison can be
changed for each individual component at a later point in time, using p9907/p9908 or by
right-clicking in the topology. All data on the electronic type plate is compared by default.
● If p9909 = 1, the serial number and the hardware version of the new replaced component
● For p9909 = 0, serial numbers and hardware versions are not automatically transferred.
The setting p9901 = 1 enables the spare parts/components replacement without tool support
to be carried out. The new serial number of the spare part is automatically transferred from
the actual topology to the reference topology and saved in the non-volatile memory.
Prerequisite is that the replaced components are of the same type and have the same order
number, e.g. "6SL3055-0AA00-5BA2". The last or last two digits of the order number
(depending on the component type) are not checked, as the HW version, for example, is
encoded in these positions. This mechanism is also applied when several components are
replaced.
Modified wiring following module replacement
In the default setting for the topology comparator, modified wiring configurations of
DRIVE-CLiQ components (e.g. cross-exchange) cannot be accepted for safety reasons and
a fault is generated.
If a cross-exchange of components is required (i.e. existing components are replaced with
other existing components, and no spare parts are used), e.g. for troubleshooting purposes,
the topology comparator must be reduced via parameter p9906 or preferably via
p9907/p9908; or as an alternative, by right-clicking in the topology.
NOTICE
In this case, incorrect insertion of components is no longer monitored.
316
same length as the old one.
will be transferred automatically from the actual topology to the target topology and then
saved to non-volatile memory.