Commissioning (software)
6.2 Performing the configuration for the D4x5-2 offline
6.2.2

Accessing the drive wizard

Integrated drive
The SIMOTION D4x5-2 contains an integrated SINAMICS S120 drive unit, which is
automatically inserted together with the SIMOTION D4x5-2 control unit in the project
navigator. The integrated drive must be operated in equidistant, isochronous mode using
PROFIdrive-compliant message frame types.
The drive wizard for the integrated STARTER is available in SIMOTION SCOUT for
configuring the integrated drive and its associated modules (e.g. SINAMICS S120 active line
modules and SINAMICS S120 motor modules).
Note
To configure the drive components of a CX32-2 controller extension, the same procedure
should be used as for the integrated drive of the SIMOTION D4x5-2 control unit.
Note
Take note of all the necessary safety precautions and rules governing connections, which
can be found in the latest SINAMICS S120 documentation on the SIMOTION SCOUT DVD.
Requirement
You have already created a project and have inserted a SIMOTION D4x5-2.
Procedure
To call the drive wizard for the configuration of your drive unit, double-click "Configure drive
unit" below "D4x5-2" > "SINAMICS Integrated" in the project navigator.
You can configure the following components:
● Infeed (e.g. SINAMICS S120 active line module)
● Drive
● Power unit (e.g. SINAMICS S120 motor module)
● Motor
● Encoder
● Option module