Functions; Function List - Mitsubishi Electric NZ2FTGN User Manual

Slice remote i/o module
Table of Contents

Advertisement

12.4

Functions

This section describes the functions of the NZ2FT-EIP.

Function list

Item
Fieldbus communication
Parameter setting
IP address acquisition method setting
Data format switching
Module parameter function
Save module parameters on coupler
Output value setting for fieldbus error
I/O value setting for Hot swap
Checking warning output (Process
alarm)
Web server functions
Item
Web server connection
Webserver via Ethernet
Login/Logout
HTTPS setting
Help display
Changing the language
Force mode
Lock force mode
Tag name function
I&M data function
Reset
Saving/loading parameter files
Initialization
Firmware update
Description
Communicates with the RJ71EIP91 using the EtherNet/IP protocol.
Communication is performed with the RJ71EIP91 via the Class1 instance
communications (constant periodic communications) or UCMM message
communications (communications at arbitrary timing).
Set the communication parameters of the NZ2FT-EIP from the setting window of the
EtherNet/IP Configuration Tool for RJ71EIP91.
Set the parameters of the NZ2FT-EIP and I/O module on the Web server.
Sets the method of acquiring an IP address.
Sets the data format received/sent from/to the RJ71EIP91 to big-endian or little-
endian.
Records the I/O module parameter settings in the non-volatile memory of the
NZ2FT-EIP.
Compatible with the NZ2FT-EIP firmware version 2.8.0 or later.
Records the I/O module parameter settings in the non-volatile memory of the
NZ2FT-EIP.
Compatible with the NZ2FT-EIP firmware version 2.7.0 or earlier.
Sets the output value of the I/O module for each case, such as when the CPU
module status of the RJ71EIP91 changes or a fieldbus error occurs.
Set the I/O value of the I/O module of when replacing the I/O module while the
power is on.
Checks whether Process alarm has occurred from the I/O module corresponding to
the warning output, and reads Process alarm data of the content.
Description
Access the Web server via the USB port or the Ethernet port.
Set whether to enable or disable the access to the Web server via the Ethernet port.
Authenticate/clear access to the Web server.
The functions will be limited if not logged in.
Encrypts the communications with the Web server.
Displays Help of the Web server.
Changes the display language of the Web server.
Inputs/outputs an arbitrary value forcibly from the Web server without being affected
by the input from an external device or by the operation result (cyclic data) of the
program.
Enables or disables the ability to switch mode to the Force mode of the Web server.
Set an arbitrary character string as the channel name of the I/O module.
Records I&M data (Identification & Maintenance) such as the installation location of
the system and the installation date.
Restarts the NZ2FT-EIP from the Web server.
Saves or loads the NZ2FT-EIP and I/O module parameter files. This function is used
when the NZ2FT-EIP is replaced.
Restores the NZ2FT-EIP to the factory default setting from the Web server.
Updates the firmware of the NZ2FT-EIP and I/O module.
Reference
Page 363 EtherNet/IP
Configuration
Page 390 Parameter list
Page 390 Parameter list
Page 390 Parameter list
Page 75 Module parameter
function
Page 390 Parameter list
Page 369 Output value setting
for fieldbus error
Page 79 I/O value setting for
Hot swap
Page 370 Checking warning
output (Process alarm)
Reference
Page 60 Connection with a
Personal Computer
Page 390 Parameter list
Page 64 Login/Logout
Page 67 HTTPS setting
Page 69 Window Layout
Page 73 Changing the
language
Page 76 Force mode
Page 390 Parameter list
Page 83 Tag name function
Page 85 I&M data function
Page 85 Resetting the coupler
Page 80 Saving/loading
parameter files
Page 86 Initialization of the
coupler
Page 87 Firmware update
12 NZ2FT-EIP
367
12.4 Functions
12

Advertisement

Table of Contents
loading