Mitsubishi Electric NZ2FTGN User Manual page 92

Slice remote i/o module
Table of Contents

Advertisement

Cannot log in to the Web server
Check the following item.
Item
Check User name/Password.
Cannot save/load the parameter file
Check the following items in order from the top. ( Page 80 Saving/loading parameter files)
Item
■For the NZ2FT-GN
Are the LINK P1 LED and LINK P2 LED on?
■For the NZ2FT-MT and NZ2FT-EIP
Are the L/A P1 LED and L/A P2 LED on or flashing?
Is the BF LED on the coupler on in red?
Is the system configuration when the parameters are saved
different from the system configuration to be loaded?
Is the parameter file invalid?
Is the voltage of the coupler power supply (24VDC) within the
specified range?
If the parameter file is still not saved/loaded even after checking all of the above and checking with the LEDs of the I/O module
and Web server, there is a risk of hardware failure in the I/O module.
Acquire the service files, and please consult your local Mitsubishi representative. ( Page 88 Acquisition of the service file)
4 WEB SERVER
90
4.4 Troubleshooting
Action
If User name/Password is forgotten, reset them by the following procedure.
(1) Power off the coupler.
(2) Remove I/O modules but leave the coupler only.
(3) Power on the coupler.
(4) Set "New user name", "New password", and "Repeat new password" on the "Change
login" window.
Action
■For the NZ2FT-GN
If the LINK P1 LED and LINK P2 LED are off, perform troubleshooting. Also, check other
LEDs. ( Page 469 NZ2FT-GN)
■For the NZ2FT-MT and NZ2FT-EIP
If the L/A P1 LED and L/A P2 LED are off, perform troubleshooting. Also, check other
LEDs. ( Page 359 When the L/A P1 LED and L/A P2 LED turn off, Page 408 When
the L/A P1 LED and L/A P2 LED turn off)
• If the BF LED is flashing in red, perform troubleshooting. Also, check other LEDs.
• If the BF LED is off, check the procedure for replacing the coupler. ( Page 49
Coupler).
Match the system configuration when saving the parameters.
Save the parameter file again and load the parameter file into the coupler.
Set the voltage value within the range of performance specifications.

Advertisement

Table of Contents
loading

Table of Contents