Program Example of NZ2FT-PBV

Precautions for programming

In NZ2FT-PBV transmission programs, interlock is provided with the following device.
• I/O data communication start command (M1000)
The following shows an example of interlock being provided in a communication program through the use of I/O data
communication start command (M1000).
Turning on I/O data communication start command (M1000) executes the I/O data communication program.

Example using the NZ2FTS-60AD4

The following example is for a program to read AI values that are obtained from A/D conversion performed on AI 0 (Channel
0) to AI 3 (Channel 3) of the analog input module.
System configuration
RJ71PB91V
Item
DP-Master (FDL address 0)
DP-Slave (FDL address 1)
10 NZ2FT-PBV
246
10.8 Program Example of NZ2FT-PBV
I/O data communication program
CPU module
Power supply module
PROFIBUS-DP module
PROFIBUS-DP compatible coupler
4ch analog input module
NZ2FT-PBV
Model
R04CPU
R61P
RJ71PB91V
NZ2FT-PBV
NZ2FTS-60AD4