Three tests can be performed using a multi-meter to
determine the condition of the stator (alternator).
TEST 1: RESISTANCE VALUE OF EACH STATOR
LEG
Measure the resistance value of each of the three stator
legs: Y1 to Y2, Y1 to Y3, and Y2 to Y3. Each test should
measure:
CONNECT
TEST
METER
LEADS TO:
Battery Charge
Y1 to Y2
Coil
Battery Charge
Y1 to Y3
Coil
Battery Charge
Y2 to Y3
Coil
NOTE
If there are any significant variations in ohm readings
between the three legs it is an indication that one of the
stator legs may be weak or failed.
TEST 2: RESISTANCE VALUE OF EACH STATOR
LEG TO GROUND
Measure the resistance value of each of the stator legs to
ground: Y1 to Ground, Y2 to Ground, Y3 to Ground.
Each test should measure:
CONNECT
TEST
METER
LEADS TO:
Battery Charge
Y1, Y2, or Y3
Coil
to Ground
ELECTRICAL
OHMS
READING
0.07 - 0.13 Ω
0.07 - 0.13 Ω
0.07 - 0.13 Ω
OHMS
READING
12
Open Line
(Infinity)
12.21