Figure 2-3 80 Volt Dc Bus From 115 And 230 Vac Source - Aerotech SOLOIST Hardware Manual

Table of Contents

Advertisement

Soloist Hardware Manual
Soloist
AUXPWR OPTION
TRANSFORMER
INTERNAL
THERMAL
SWITCH
RED 56v
AC1
GRN 0v
AC2
4
YEL 56v
BLK 0v
FRAME GROUND
AC1
AC2
Soloist
AUXPWR OPTION
TRANSFORMER
INTERNAL
THERMAL
SWITCH
RED 56v
AC1
GRN 0v
AC2
4
YEL 56v
BLK 0v
FRAME GROUND
AC1
AC2
Figure 2-3
 Figure 2-3 is shown only for reference. For the most recent .Dwg files, see your
software CD ROM, which includes a .Dwg file viewer.
www.aerotech.com
PRIMARY FUSE
4A SLO-BLO
#18 WHT
splice
#18 WHT
115v BLK
100v ORN
2
0v GRAY
115v BRN
100v GRN
2
splice
0v BLU
TV0.3-56 WIRING
PRIMARY = 115VAC
SECONDARY = 56VAC (80VDC BUS)
TRANSFORMER P/N EAX01006
PRIMARY FUSE
3A SLO-BLO
#18 WHT
splice
#18 WHT
115v BLK
100v ORN
3
splice
0v GRAY
115v BRN
100v GRN
3
splice
0v BLU
TV0.3-56 WIRING
PRIMARY = 230VAC
SECONDARY = 56VAC (80VDC BUS)
TRANSFORMER P/N EAX01006
80 Volt DC Bus from 115 and 230 VAC Source
Installation and Configuration
AC HI
115VAC
AC LO
50/60 HZ
INPUT
SAFTEY
NOTES:
1. THE AUXPWR OPTION IS USED WHEN THE MAIN SUPPLY POWER IS BELOW
100VAC. TYPICALLY 28-56VAC INPUT. THIS COREESPONDS TO A BUS
VOLTAGE OF 40-80VDC.
2. FOR 100VAC PRIMARY INPUT, PARALLEL THE 100VAC TAPS AND LEAVE
THE 115VAC TAPS UNTERMINATED.
3. FOR 200VAC PRIMARY INPUT, SERIES THE 100VAC TAPS AND LEAVE THE
115VAC TAPS UNTERMINATED.
4. WHEN USING AN ISOLATION TRANSFORMER, EARTH GROUNDING OF "AC2"
INPUT TAP REDUCES ELECTRICAL AND AUDIBLE NOISE EMMISSIONS AND
PROVIDES INCREASED SERVO PERFORMANCE.
5. IT IS RECOMMENDED THAT THE OPTIONAL AND MAIN SUPPLIES ARE
TURNED ON AT THE SAME TIME TO ENSURE PROPER SOFT START
OPERATION.
6. ADDITIONAL OR ALTERNATIVE FUSING MAY BE REQUIRED FOR OPTIMUM
PROTECTION.
AC HI
230VAC
AC LO
50/60 HZ
INPUT
SAFTEY
Soloist
AUXPWR INTERCONNECT
(80VDC BUS / TV0.3-56)
620B1346-2
620B1346-201.DWG
2-7