2.2.2. Motor Supply Connections (TB201)

N O T E : This product requires two power supply connections. The Motor Supply and Control Supply
must both be connected for proper operation.
Motor power is applied to the Nmark CLS at the four terminals of the Motor Supply connector (TB201). The
DC+ and DC- inputs are internally fused.
W A R N I N G : Do not operate the Nmark CLS without the safety ground connection in place.
MOTOR SUPPLY
20A MAX
Table 2-4:
Motor Supply Input Wiring
Pin
Description
DC+
0 to +40 Volt DC Input Range
RET
Return for DC Input
DC-
0 to -40 Volt DC Input Range
Protective Ground (Required for Safety)
N O T E : Wire insulation rated for 300 V.
Table 2-5:
Motor Supply Mating Connector (TB201)
Type
4-Pin Terminal Block
www.aerotech.com
TB201
DC+
RET
DC-
+/- 40V
Figure 2-2:
Motor Bus Input Connections
Aerotech P/N
ECK01581
Chapter 2
Installation and Configuration
Screw Torque
Phoenix P/N
Value: Nm
1757035
0.5 - 0.6
Ground
DC+
RET
DC-
Recommended Wire Size
2
2.1 mm
(#14 AWG)
2
2.1 mm
(#14 AWG)
2
2.1 mm
(#14 AWG)
2
2.1 mm
(#14 AWG)
Wire Size:
2
mm
[AWG]
3.3 - 0.0516 [12-30]