Electronic gear selection function

With the input devices CM1 (Electric gear selection 1) and CM2 (Electronic gear selection 2), the numerator of the electronic
gear (CMX) can be selected. The electronic gear numerator (CMX) switches at the same time as CM1 and CM2 are turned on
or off. If a shock occurs at switching, use the position smoothing ([Pr. PB03 Position command speed adjustment time
constant (position smoothing)]) to relieve the shock.
*1
Input device
CM2
0
0
1
1
*1 0: OFF
1: ON
3 BASIC FUNCTION
114
3.10 Electronic gear function [A]
CM1
0
1
0
1
Electronic gear - Numerator
[Pr. PA06]
[Pr. PC32]
[Pr. PC33]
[Pr. PC34]