Proline Prosonic Flow E 100 HART
Parameter
Actual diagnostics
Previous diagnostics
Operating time from restart
Operating time
Endress+Hauser
Parameter overview with brief description
Prerequisite
A diagnostic event has occurred.
Two diagnostic events have already
occurred.
12.8

Diagnostic list

Up to 5 currently pending diagnostic events can be displayed in the Diagnostic list
submenu along with the associated diagnostic information. If more than 5 diagnostic
events are pending, the events with the highest priority are shown on the display.
Navigation path
Diagnostics → Diagnostic list
To call up the measures to rectify a diagnostic event:
• Via Web browser →  75
• Via "FieldCare" operating tool →  76
• Via "DeviceCare" operating tool →  76
12.9

Event logbook

12.9.1

Reading out the event logbook

A chronological overview of the event messages that have occurred is provided in the
Events list submenu.
Navigation path
Diagnostics menu → Event logbook submenu → Event list
A maximum of 20 event messages can be displayed in chronological order.
The event history includes entries for:
• Diagnostic events →  77
• Information events →  82
Diagnostics and troubleshooting
Description
Shows the current occured diagnostic
event along with its diagnostic
information.
If two or more messages occur
simultaneously, the message with
the highest priority is shown on
the display.
Shows the diagnostic event that
occurred prior to the current diagnostic
event along with its diagnostic
information.
Shows the time the device has been in
operation since the last device restart.
Indicates how long the device has been
in operation.
User interface
Symbol for diagnostic
behavior, diagnostic code
and short message.
Symbol for diagnostic
behavior, diagnostic code
and short message.
Days (d), hours (h),
minutes (m) and seconds
(s)
Days (d), hours (h),
minutes (m) and seconds
(s)