Proline Prosonic Flow E 100 HART
Parameter
Assign current output
Damping output 1
Measuring mode output 1
Assign frequency output
Damping output 1
Measuring mode output 1
Assign pulse output
Measuring mode output 1
Operating mode totalizer
*
Visibility depends on order options or device settings
Endress+Hauser
Parameter overview with brief description
Prerequisite
The Frequency option is
selected in the Operating
mode parameter (→  49)
parameter.
The Pulse option is selected in
the Operating mode
parameter parameter.
Description
Select process variable for
current output.
Set reaction time for output
signal to fluctuations in the
measured value.
Select measuring mode for
output.
Select process variable for
frequency output.
Set reaction time for output
signal to fluctuations in the
measured value.
Select measuring mode for
output.
Select process variable for
pulse output.
Select measuring mode for
output.
Select totalizer calculation
mode.
Commissioning
Selection / User
Factory setting
entry
• Off
Volume flow
• Volume flow
• Mass flow
• Sound velocity
• Flow velocity
*
• Temperature
*
• Acceptance rate
*
• Signal strength
• Signal to noise
*
ratio
*
• Turbulence
*
• Signal asymmetry
0 to 999.9 s
1 s
• Forward flow
Forward flow
• Forward/Reverse
flow
• Reverse flow
compensation
• Off
Off
• Volume flow
• Mass flow
• Sound velocity
• Flow velocity
• Temperature
• Acceptance rate
• Signal strength
• Signal to noise
ratio
• Turbulence
• Signal asymmetry
0 to 999.9 s
1 s
• Forward flow
Forward flow
• Forward/Reverse
flow
• Reverse flow
• Reverse flow
compensation
• Off
Off
• Volume flow
• Mass flow
• Forward flow
Forward flow
• Forward/Reverse
flow
• Reverse flow
• Reverse flow
compensation
• Net flow total
Net flow total
• Forward flow total
• Reverse flow total