Diagnostic information

6.
In the Reference density parameter, enter the reference density of the fluid.
7.
In the Reference pressure parameter, enter the reference pressure of the fluid.
8.
In the Reference temperature parameter, enter the fluid temperature associated with
the reference density.
9.
In the Reference Z-factor parameter, enter the value 1.
10. If specific heat capacity is to be measured:
In the Specific heat capacity parameter, enter the heat capacity of the fluid.
11. In the Z-factor parameter, enter the value 1.
12. In the Dynamic viscosity parameter, enter the viscosity of the fluid under operating
conditions.
9
Diagnostic information
Faults detected by the self-monitoring system of the measuring device are displayed as a
diagnostic message in alternation with the operational display. The message about remedial
measures can be called up from the diagnostic message, and contains important information
on the fault.