Endress+Hauser Proline Prosonic Flow E 100 HART Operating Instructions Manual page 61

Ultrasonic time-of-flight flowmeter
Table of Contents

Advertisement

Proline Prosonic Flow E 100 HART
Parameter
Format display
Value 1 display
0% bargraph value 1
100% bargraph value 1
Decimal places 1
Value 2 display
Decimal places 2
Value 3 display
0% bargraph value 3
100% bargraph value 3
Decimal places 3
Value 4 display
Endress+Hauser
Parameter overview with brief description
Prerequisite
A local display is provided.
A local display is provided.
A local display is provided.
A local display is provided.
A measured value is specified
in the Value 1 display
parameter.
A local display is provided.
A measured value is specified
in the Value 2 display
parameter.
A local display is provided.
A selection was made in the
Value 3 display parameter.
A selection was made in the
Value 3 display parameter.
A measured value is specified
in the Value 3 display
parameter.
A local display is provided.
Description
Select how measured values
are shown on the display.
Select the measured value that
is shown on the local display.
Enter 0% value for bar graph
display.
Enter 100% value for bar
graph display.
Select the number of decimal
places for the display value.
Select the measured value that
is shown on the local display.
Select the number of decimal
places for the display value.
Select the measured value that
is shown on the local display.
Enter 0% value for bar graph
display.
Enter 100% value for bar
graph display.
Select the number of decimal
places for the display value.
Select the measured value that
is shown on the local display.
Commissioning
Selection / User
Factory setting
entry
• 1 value, max. size
1 value, max. size
• 1 bargraph + 1
value
• 2 values
• 1 value large + 2
values
• 4 values
• Mass flow
Volume flow
• Sound velocity
• Flow velocity
*
• Temperature
• Volume flow
• Current output 1
*
• Acceptance rate
*
• Signal asymmetry
*
• Turbulence
*
• Signal strength
• Current output 1
• Signal to noise
*
ratio
• Totalizer 1
• Totalizer 2
• Totalizer 3
Signed floating-point
Country-specific:
number
• 0 m³/h
• 0 ft³/h
Signed floating-point
Depends on country
number
and nominal
diameter
• x
x.xx
• x.x
• x.xx
• x.xxx
• x.xxxx
For the picklist, see
None
the Value 1 display
parameter
• x
x.xx
• x.x
• x.xx
• x.xxx
• x.xxxx
For the picklist, see
None
the Value 1 display
parameter (→  61)
Signed floating-point
Country-specific:
number
• 0 m³/h
• 0 ft³/h
Signed floating-point
0
number
• x
x.xx
• x.x
• x.xx
• x.xxx
• x.xxxx
For the picklist, see
None
the Value 1 display
parameter (→  61)
61