Agilent Technologies 8163A Programming Manual page 95

Lightwave multimeter lightwave measurement system lightwave multichannel system
Hide thumbs Also See for 8163A:
Table of Contents

Advertisement

Signal Generation – The SOURce Subsystem
command:
syntax:
description:
parameters:
N OT E
response:
example:
affects:
command:
syntax:
description:
parameters:
NO TE
response:
example:
affects:
Agilent 8163A Lightwave Multimeter, Agilent 8164A Lightwave Measurement System, & Agilent 8166A Lightwave Multichannel
System, Third Edition
[:SOURce[n]][:CHANnel[m]]:AM:SOURce[l]
[:SOURce[n]][:CHANnel[m]]:AM:SOURce[l]<wsp> INT|INT1|INT2|EXT|0|1|2
Selects the type or source of the modulation of the laser output.
0, INT1, or INTernal:
1, COHCtrl, or INT2:
2, AEXTernal, or EXT:
3 or DEXTernal:
4 or LFCohctrl:
5 or WVLLocking:
6 or BACKplane:
Use [l] to set the modulation source of the upper or lower wavelength laser source of a
dual-wavelength laser source or a return loss module with an internal dual-wavelength la-
ser source. The default value of [l] is 1, the lower wavelength source. The upper wave-
length source is denoted by 2.
none
sour2:am:sour int
All laser source, DFB source, and tunable laser modules can use internal digital modula-
tion
All other modulation modes are only available with tunable laser modules.
[:SOURce[n]][:CHANnel[m]]:AM:SOURce[l]?
[:SOURce[n]][:CHANnel[m]]:AM:SOURce[l]?
Returns the type or source of the modulation of the laser output.
0:
internal digital modulation
1:
coherence control
2:
external analog modulation
3:
external digital modulation
4:
low frequency coherence control
5:
wavelength locking
6:
external digital modulation using Input Trigger Connector
Use [l] to query the modulation source of the upper or lower wavelength laser source of a
dual-wavelength laser source or a return loss module with an internal dual-wavelength la-
ser source. The default value of [l] is 1, the lower wavelength source. The upper wave-
length source is denoted by 2.
none
sour2:am:sour?
All laser source, DFB source, and tunable laser modules can use internal digital modula-
tion
All other modulation modes are only available with tunable laser modules.
Measurement Operations & Settings
internal digital modulation
coherence control
external analog modulation
external digital modulation
low frequency coherence control
wavelength locking
external digital modulation using Input Trigger Connector