Agilent Technologies 8163A Programming Manual page 38

Lightwave multimeter lightwave measurement system lightwave multichannel system
Hide thumbs Also See for 8163A:
Table of Contents

Advertisement

Specific Commands
Command
:OUTPut[n][:CHANnel[m]]
:CONNection/?
:PATH/?
[:STATe]/?
:READ[n][:CHANnel[m]][:SCALar]
:POWer[:DC]?
:RETurnloss?
:RETurnloss?
:SENSe[n][:CHANnel[m]]:CORRection
[:LOSS][:INPut][:MAGNitude]/?
:COLLECT:ZERO
:COLLECT:ZERO?
:COLLECT:ZERO:ALL
:SENSe[n][:CHANnel[m]]:FUNCtion
:PARameter:LOGGing/?
:PARameter:MINMax/?
:PARameter:STABility/?
:RESult?
:STATe/?
:THReshold/?
:SENSe[n][:CHANnel[m]]:POWer
:ATIMe/?
:RANGe[:UPPer]/?
:RANGe:AUTO/?
:REFerence/?
UNIT/?
:WAVelength/?
38
Table 4
Specific Command Summary (continued)
Description
Selects or returns Analog Output parameter.
Sets or returns the regulated path.
Sets a source's output terminals to open or closed or returns the
current status of a source's output terminals.
Reads the current power value from a sensor.
Reads the current return loss value.
Returns the current return loss value.
Sets or returns the value of correction data for a sensor.
Executes a zero calibration of a sensor module.
Returns the current zero state of a sensor module.
Executes a zero calibration of all sensor modules.
Sets or returns the number of samples and the averaging time, t
for logging.
Sets or returns the minmax mode and the window size.
Sets or returns the total time, delay time and the averaging time, t
for stability.
Returns the data array of the last function.
Enables/disables the function mode or returns whether the function
mode is enabled.
Sets or returns the threshold value and the start mode.
Sets or returns the average time of a sensor.
Sets or returns the most positive signal entry expected for a sensor. page 84
Sets or returns the range of a sensor to produce the most dynamic
range without overloading.
Sets or returns the reference level of a sensor.
Sets or returns the units used for absolute readings on a sensor.
Sets or returns the wavelength for a sensor.
Agilent 8163A Lightwave Multimeter, Agilent 8164A Lightwave Measurement System,
& Agilent 8166A Lightwave Multichannel System, Third Edition
Specific Command Summary
Page
page 92
page 92
page 93
page 75
page 76
page 76
page 76
page 77
page 77
page 77
,
page 78
avg
page 79
,
page 80
avg
page 81
page 82
page 83
page 83
page 85
page 85
page 88
page 88