Crosstalk Test; System Dynamic Range Test - Agilent Technologies ENA Series Service Manual

Rf network analyzers
Hide thumbs Also See for ENA Series:
Table of Contents

Advertisement

Performance Tests
E5061A Performance Test Record (for Option 150/250)

Crosstalk Test

Direction: S21
Frequency range [Hz]
300 k - 100 M
100 M - 1.5 G
Direction: S12 (Option 250 only)
Frequency range [Hz]
300 k - 100 M
100 M - 1.5 G

System Dynamic Range Test

For Serial Prefix : JP1KL or MY441
Direction: S21
Frequency range [Hz]
300 k - 100 M
100 M - 1.5 G
300 k - 100 M
100 M - 1.5 G
Direction: S12 (Options 250 only)
Frequency range [Hz]
300 k - 100 M
100 M - 1.5 G
300 k - 100 M
100 M - 1.5 G
For Serial Prefix : MY442 and above
Direction: S21
Frequency range [Hz]
300 k - 1 M
1 M - 100 M
42
IF bandwidth [Hz]
Test limit [dB]
10
10
IF bandwidth [Hz]
Test limit [dB]
10
10
IF bandwidth [Hz]
Test limit [dB]
10
10
3 k
3 k
IF bandwidth [Hz]
Test limit [dB]
10
10
3 k
3 k
IF bandwidth [Hz]
Test limit [dB]
10
10
Test result [dB]
 -110
 -110
Test result [dB]
 -110
 -110
Test result [dB]
 -115
 -115
 -90
 -90
Test result [dB]
 -115
 -115
 -90
 -90
Test result [dB]
 -115
 -120
Chapter 2

Advertisement

Table of Contents
loading

This manual is also suitable for:

E5061aE5062a

Table of Contents