Rmon Alarm - D-Link xStack DWS-3200 Series Cli Manual

Layer 2+ stackable gigabit ethernet switches with optional xg uplinks
Hide thumbs Also See for xStack DWS-3200 Series:
Table of Contents

Advertisement

DXS/DWS-3200 series CLI Reference Guide

rmon alarm

The rmon alarm Global Configuration mode command configures alarm conditions. To remove an alarm, use the
no form of this command.
Syntax
rmon alarm index variable interval rthreshold fthreshold revent fevent [type type] [startup direction] [owner
name]
no rmon alarm index
Parameters
index — Specifies the alarm index. (Range: 1-65535)
variable — Specifies the object identifier of the variable to be sampled.
interval — Specifies the interval in seconds during which the data is sampled and compared with rising and
falling thresholds. (Range: 0-2147483647)
rthreshold — Specifies the rising threshold. (Range: 0-2147483647)
fthreshold — Specifies the falling threshold. (Range: 0-2147483647)
revent — Specifies the event index used when a rising threshold is crossed.
(Range: 1-65535)
fevent — Specifies the event index used when a falling threshold is crossed.
(Range: 1-65535)
type — Specifies the method used for sampling the selected variable and calculating the value to be
compared against the thresholds. Possible values are absolute and delta.
If the method is absolute, the value of the selected variable is compared directly with the thresholds at the
end of the sampling interval. If the method is delta, the selected variable value of the last sample is sub-
tracted from the current value, and the difference is compared with the thresholds.
direction — Specifies the alarm that may be sent when this entry is first set to valid. Possible values are
rising, rising-falling and falling.
If the first sample (after this entry becomes valid) is greater than or equal to rthreshold and direction is equal
to rising or rising-falling, a single rising alarm is generated. If the first sample (after this entry becomes
valid) is less than or equal to fthreshold and direction is equal to falling or rising-falling, a single falling alarm
is generated.
name — Specifies the name of the person who configured this alarm. If unspecified, the name is an empty
string.
Default Configuration
The type is absolute.
The startup direction is rising-falling.
Command Mode
Global Configuration mode
User Guidelines
There are no user guidelines for this command.
Page 257

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xstack dxs-3200 series

Table of Contents