Test operation mode in MR Configurator2

• When the test operation mode is selected with the slide switches (SW1-1 and SW1-2), the commands from
the master station (controller) are not accepted.
Test operation mode
■JOG operation
Jog operation can be performed without the master station (controller). Use this operation with the forced stop reset. This
operation may be used independently of whether servo-on or servo-off and whether a master station (controller) is connected
or not.
Operate on the jog operation screen of MR Configurator2.
• Operation pattern
Item
Servo motor speed [r/min]
Accel./decel. time constant [ms]
• Operation method
When the check box of "Rotation only while the CCW or CW button is being pushed." is checked.
Operation
Forward rotation start
Reverse rotation start
Stop
Forced stop
When the check box of "Rotation only while the CCW or CW button is being pushed." is not checked.
Operation
Forward rotation start
Reverse rotation start
Stop
Forced stop
4 STARTUP
48
4.5 Test operation mode
Initial value
200
1000
Screen operation
Keep pressing "Forward CCW".
Keep pressing "Reverse CW".
Release "Forward CCW" or "Reverse CW".
Click "Forced Stop".
Screen operation
Click "Forward CCW".
Click "Reverse CW".
Click "Stop".
Click "Forced Stop".
Setting range
0 to Maximum speed
0 to 50000