Mitsubishi Electric MELSERVO-MR-J4 GF Series Instruction Manual page 172

Cc-link ie field network interface servo amplifier
Table of Contents

Advertisement

No.
Symbol
PB45
CNHF
PB46
NH3
PB47
NHQ3
PB48
NH4
PB49
NHQ4
PB50
NH5
PB51
NHQ5
PB52
VRF21
PB53
VRF22
PB54
VRF23
PB55
VRF24
PB56
VRF21B
PB57
VRF22B
PB58
VRF23B
PB59
VRF24B
PB60
PG1B
PB61
PB62
PB63
PB64
7 PARAMETERS
170
7.1 Parameter list
Name
Command notch filter
Machine resonance suppression filter 3
Notch shape selection 3
Machine resonance suppression filter 4
Notch shape selection 4
Machine resonance suppression filter 5
Notch shape selection 5
Vibration suppression control 2 - Vibration frequency
Vibration suppression control 2 - Resonance frequency
Vibration suppression control 2 - Vibration frequency damping
Vibration suppression control 2 - Resonance frequency damping
Vibration suppression control 2 - Vibration frequency after gain switching
Vibration suppression control 2 - Resonance frequency after gain
switching
Vibration suppression control 2 - Vibration frequency damping after gain
switching
Vibration suppression control 2 - Resonance frequency damping after
gain switching
Model loop gain after gain switching
For manufacturer setting
Initial
Unit
Detailed
value
explanation
0000h
Motion mode
4500
[Hz]
0000h
4500
[Hz]
0000h
4500
[Hz]
0000h
100.0
[Hz]
100.0
[Hz]
0.00
0.00
0.0
[Hz]
0.0
[Hz]
0.00
0.00
0.0
[rad/s]
0.0
0000h
0000h
0000h