Mitsubishi Electric MELSERVO-MR-J4 GF Series Instruction Manual page 191

Cc-link ie field network interface servo amplifier
Table of Contents

Advertisement

No./symbol/
Setting
Function
name
digit
PT19
Set an address increasing side of the position range output address. The combination of the upper
*LPPL
and lower digits makes one address. Using [Pr. PT19] to [Pr. PT22], set a range in which Index
Position range
2D17h Status DO7 bit2 (Position range) turns on.
output address +
(lower four digits)
Setting address:
PT20
*LPPH
Position range
output address +
(upper four digits)
The unit can be changed to 10
[Pr. PT01].
The unit [degree] is used with servo amplifiers with software version A6 or later.
Setting range: 8000 0000h to 7FFF FFFFh (-2147483648 to 2147483647)
PT21
Set an address decreasing side of the position range output address. The combination of the upper
*LNPL
and lower digits makes one address. Using [Pr. PT19] to [Pr. PT22], set a range in which Index
Position range
2D17h Status DO7 bit2 (Position range) turns on.
output address -
(lower four digits)
Setting address:
PT22
*LNPH
Position range
output address -
(upper four digits)
The unit can be changed to 10
[Pr. PT01].
The unit [degree] is used with servo amplifiers with software version A6 or later.
Setting range: 8000 0000h to 7FFF FFFFh (-2147483648 to 2147483647)
Upper four digits Lower four digits
[Pr. PT19]
[Pr. PT20]
STM
(STM-4)
[μm], 10
[inch], 10
Upper four digits Lower four digits
[Pr. PT21]
[Pr. PT22]
STM
(STM-4)
[μm], 10
[inch], 10
-3
[degree], or [pulse] with the setting of
-3
[degree], or [pulse] with the setting of
7.2 Detailed list of parameters
Initial
Control
value
mode
[unit]
CP
PS
0000h
Refer to
Function
column
for unit.
0000h
Refer to
Function
column
for unit.
0000h
Refer to
Function
column
for unit.
0000h
Refer to
Function
column
7
for unit.
7 PARAMETERS
189

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-mr-j4 gf rj series

Table of Contents