4. STARTUP

4.5.1 Test operation mode in MR Configurator2

(1) Test operation mode
(a) Jog operation
Jog operation can be performed without the master station (controller). Use this operation with the
forced stop reset. This operation may be used independently of whether servo-on or servo-off and
whether a master station (controller) is connected or not.
Operate on the jog operation screen of MR Configurator2.
1) Operation pattern
Item
Servo motor speed [r/min]
Accel./decel. time constant
[ms]
2) Operation method
a) The check box "Rotation only while the CCW or CW button is being pushed" is checked.
Operation
Forward rotation start
Reverse rotation start
Forced stop
b) The check box "Rotation only while the CCW or CW button is being pushed" is unchecked.
Operation
Forward rotation start
Reverse rotation start
Forced stop
POINT
When the test operation mode is selected with the slide switches (SW1-1 and
SW1-2), the servo amplifier will not receive commands from the master station
(controller).
Initial value
200
1000
Stop
Release "Forward CCW" or "Reverse CW".
Stop
Setting range
0 to Maximum speed
0 to 50000
Screen operation
Keep pressing "Forward CCW".
Keep pressing "Reverse CW".
Click "Forced Stop".
Screen operation
Click "Forward CCW".
Click "Reverse CW".
Click "Stop".
Click "Forced Stop".