Chapter 10 Object Dictionary; Object Dictionary List - Mitsubishi Electric MELSERVO-MR-J4 GF Series Instruction Manual

Cc-link ie field network interface servo amplifier
Table of Contents

Advertisement

10
OBJECT DICTIONARY
Each data such as control parameters, command values, and feedback values is handled as an object composed of an
address, object name, data type, access rule, and other elements. The object data can be exchanged between the master
station (controller) and the slave stations (servo amplifiers). The aggregate of these objects is called object dictionary.
10.1

Object dictionary list

The object dictionary list structure is as follows.
Item
Data Type
Access
Variable mapping
Default
Range
Units
EEP-ROM
Parameter
Index
Sub
Name and function
Index
1000
0
Device Type
This displays the servo drive
defined with the CiA 402 profile.
1008
0
Manufacturer Device Name
The number of characters (N) of
the model name of the servo
amplifier is returned.
1 to N
Manufacturer Device Name
The model name of the servo
amplifier is returned.
1009
0
Manufacturer Hardware Version
The number of characters (2) of
the hardware version of the
network module is returned.
1 to 2
Manufacturer Hardware Version
The hardware version of the
servo amplifier is returned.
100A
0
Manufacturer Software Version
The number of characters (3) of
the software version of the servo
amplifier is returned.
1 to 3
Manufacturer Software Version
The software version of the servo
amplifier is returned.
10 OBJECT DICTIONARY
252
10.1 Object dictionary list
Explanation
Indicates the object size.
Indicates whether the object can be read or written.
ro: Only reading is available.
wo: Only writing is available.
rw: Reading and writing are available.
Indicates whether the object can be mapped in cyclic communication.
Indicates the initial value of the object.
Indicates the object range. If a value outside the range is written, a parameter external error (error code CCD4h) occurs.
Indicates the object unit.
-: No unit
r/min, mm/s: In the linear servo motor control mode, the unit is mm/s. In other control modes, the unit is r/min.
pos units: This is the positioning command unit.
STM
The unit can be changed to 10
STM can be changed with the "Feed length multiplication" (STM) setting of [Pr. PT03].
Indicates whether data can be stored in the non-volatile memory.
: Data cannot be stored in the non-volatile memory. The value of the data written from the controller returns to the
value of "Default" when the power is shut off.
: Data can be stored in the non-volatile memory with [Store Parameters (1010h)].
Data is saved in the servo parameter corresponding to the object. For the corresponding servo parameters, refer to
"Parameter".
Indicates where data is stored in the non-volatile memory.
Data
Access
Type
U32
ro
VISIBLE
ro
STRING
VISIBLE
ro
STRING
VISIBLE
ro
STRING
(STM-4)
-3
[μm], 10
[inch], 10
[degree], or [pulse] with the setting of [Pr. PT01].
Variable
Default
mapping
Impossible
00020192h
Impossible
Impossible
Impossible
Range
Units
EEP-
ROM
00020192h
(fixed)
Parameter

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-mr-j4 gf rj series

Table of Contents