Roll feed display function
■During normal use
When the roll feed display function is used, the status display of the current position and command position at start is 0. When
the point table is selected, the target position of the point table set at the command position is displayed.
INP/S_INP
(In-position)
Servo motor speed
Controlword bit 4
(New set-point)
Target point table
Current position
Command position
■At temporary stop
During temporary stop, the motor stop position is displayed for both the current position and the command position.
At restart after canceling the temporary stop, the current position and command position are updated again from the stop
position.
INP/S_INP
(In-position)
Servo motor speed
Controlword bit 4
(New set-point)
Controlword bit 8 (Halt)
Target point table
Current position
Command position
6 SERVO MOTOR DRIVING
138
6.2 Point table mode (pt)
ON
OFF
Forward
rotation
0 r/min
Reverse
rotation
ON
OFF
0
0
0
0
10.00
0
Update the display from 0 by Start
ON
OFF
Forward
rotation
0 r/min
Reverse
rotation
ON
OFF
ON
OFF
0
0
0
0
10.00
0
Motor stop position
1
10.00
0
10.00
8.00
0
When the point table in which the feed length
is set to 8 is selected
1
6.20
6.20
6.20
6.20
Restart from the temporary stop position
2
8.00
8.00
10.00
10.00
10.00