No./symbol/
Setting
name
digit
PN13
_ _ x x
**SNMKA
Subnet mask
setting A
x x _ _
PN14
_ _ x x
**SNMKB
Subnet mask
setting B
x x _ _
PN18
_ _ x x
**IPAFA
IP address filter
A
x x _ _
PN19
_ _ x x
**IPAFB
IP address filter
B
x x _ _
PN20
_ _ x x
**IPFRA
IP address filter
A range setting
_ x _ _
x _ _ _
PN21
_ _ x x
**IPFRB
IP address filter
B range setting
x x _ _
7 PARAMETERS
198
7.2 Detailed list of parameters
Function
Subnet mask setting 2
Set the 2nd octet of the subnet mask in hexadecimal.
Set the subnet mask assigned by the network administrator.
When both [Pr. PN13] and [Pr. PN14] are set to "0000h", the 2nd octet is "255".
The subnet mask can also be changed simultaneously by the SLMP command (IPAddressSet).
Setting range: 00h to FFh
Subnet mask setting 1
Set the 1st octet of the subnet mask in hexadecimal.
Set the subnet mask assigned by the network administrator.
When both [Pr. PN13] and [Pr. PN14] are set to "0000h", the 1st octet is "255".
The subnet mask can also be changed simultaneously by the SLMP command (IPAddressSet).
Setting range: 00h to FFh
Subnet mask setting 4
Set the 4th octet of the subnet mask in hexadecimal.
Set the subnet mask assigned by the network administrator.
The subnet mask can also be changed simultaneously by the SLMP command (IPAddressSet).
Setting range: 00h to FFh
Subnet mask setting 3
Set the 3rd octet of the subnet mask in hexadecimal.
Set the subnet mask assigned by the network administrator.
When both [Pr. PN13] and [Pr. PN14] are set to "0000h", the 3rd octet is "255".
The subnet mask can also be changed simultaneously by the SLMP command (IPAddressSet).
Setting range: 00h to FFh
IP address filter 2
Set the 2nd octet of the IP address of the network device allowed to be connected in hexadecimal.
When both [Pr. PN18] and [Pr. PN19] are set to "0000h", the function is disabled.
Setting range: 00h to FFh
IP address filter 1
Set the 1st octet of the IP address of the network device allowed to be connected in hexadecimal.
When both [Pr. PN18] and [Pr. PN19] are set to "0000h", the function is disabled.
Setting range: 00h to FFh
IP address filter 4
Set the 4th octet of the IP address of the network device allowed to be connected in hexadecimal.
When both [Pr. PN18] and [Pr. PN19] are set to "0000h", the function is disabled.
Setting range: 00h to FFh
IP address filter 3
Set the 3rd octet of the IP address of the network device allowed to be connected in hexadecimal.
When both [Pr. PN18] and [Pr. PN19] are set to "0000h", the function is disabled.
Setting range: 00h to FFh
IP address filter 2 range specification
Set a value for the 2nd octet range of the IP address of the network device allowed to be connected
in hexadecimal. The range for the IP address of the network device allowed to be connected is
between [Pr. PN18 (_ _ x x)] and [Pr. PN20 (_ _ x x)].
Setting "00h" disables the function.
Setting range: 00h to FFh
For manufacturer setting
IP address filter 4 range specification
Set a value for the 4th octet range of the IP address of the network device allowed to be connected
in hexadecimal. The range for the IP address of the network device allowed to be connected is
between [Pr. PN19 (_ _ x x)] and [Pr. PN21 (_ _ x x)].
Setting "00h" disables the function.
Setting range: 00h to FFh
IP address filter 3 range specification
Set a value for the 3rd octet range of the IP address of the network device allowed to be connected
in hexadecimal. The range for the IP address of the network device allowed to be connected is
between [Pr. PN19 (x x _ _)] and [Pr. PN21 (x x _ _)].
Setting "00h" disables the function.
Setting range: 00h to FFh
Initial
Control
value
mode
[unit]
CP
PS
00h
00h
00h
00h
00h
00h
00h
00h
00h
0h
0h
00h
00h

Advertisement