Removal - Festo MSE6-E2M Operating Instruction

Energy efficiency module
Table of Contents

Advertisement

Removal

Error
Meaning
channel
m = module
number 1
Error number 26, actuator power supply undervoltage;
Depending on the parameterisation, the module reports the error when monitoring is activated.
Input signals will, however, still be processed.
Am.0
Load voltage U
below the permitted
range
Error number 29, error in parameterisation;
Depending on the parameterisation, the module reports the error when monitoring is activated.
Input signals will, however, still be processed. The parameter values entered will be ignored. The
module operates internally with the last valid parameter values.
– Monitor limit
Em.0 ...
Em.3
values startup
– Unit pressure
– Unit flow rate
– Unit Consumption
– Flow standard
– Pressure change
sample time
Channel-dependent
error distinction
Tab. 63: Module-specific error numbers
11
Removal
The settings are not saved in the product. Save the settings if necessary, e.g. on the higher-level
controller.
Disassemble the product in the following sequence:
1. De-energise the compressed air supply and power supply.
2. Exhaust the energy efficiency module.
3. Disconnect the pneumatic ports.
4. Disconnect all electrical cables.
5. Loosen the screws from all mounting brackets, one after the other. Start with the screws beneath
the product.
78
Remedy
– Check load voltage U
OUT/A
increase if necessary.
– Check the wiring of the load voltage
supply and repair if required.
– Check parameterisation and parame-
terise again with correct parameters,
valid parameters è 9.3 Overview of
module parameters.
Enable parameter
and
Monitoring: 4828 +
OUT/A
m * 64 + 0, Bit 2,
monitoring actuator
power supply under-
voltage è Tab. 45
Monitor module
parameter.
Monitoring: 4828 +
m * 64 + 0 (bit 7)
monitoring of param-
eter error è Tab. 45
Monitor module
parameter.