Commissioning
5. Update the hardware catalogue: 'Options' > 'Update Catalog'.
Ä All available CPX modules are shown in the hardware catalogue under:
\PROFINET IO\Additional Field Devices\Valves\Festo MSE Air Supply
Setting up automation project and controller
1. Open the hardware catalogue with the 'View' > 'Catalog' command.
2. Expand the controller in the hardware catalogue, e.g. 'SIMATIC 300' and the folder structure.
3. Expand the 'RACK-300' folder.
4. Add the profile rail of the controller.
5. Reproduce the controller configuration using the components from the rack rail table in the
hardware catalogue.
Row 1, 'Slot 1', is reserved, e.g. or a fixed power supply.
Creating a PROFIBUS network
1. Open the 'Properties...' dialogue. Right-click on the interface, e.g. select X2 and 'Object Proper-
ties'.
2. Switch to the 'General' tab.
3. Click the 'Properties' button to open the 'Properties Ethernet...' dialogue.
4. Create a new network: click on the 'New' button and adjust specific settings.
5. Right-click on interface, e.g. X2 and 'Insert PROFINET IO System'.
Add PROFINET station
Drag the status symbol MSE6-C2M-5000-FB44 from the hardware catalogue to the bus line of the
PROFINET-IO system.
\PROFINET-IO\Additional Field Devices\Valves\Festo MSE Air Supply
– MSE6-C2M-5000-FB44
Assign device names, Device Name
1. Assign the device name with the 'PLC' > 'Ethernet' > 'Assign Device Name' command.
2. Find a device: click on the 'Update' button.
3. Select the device. Click on the 'Assign name' button.
Sending hardware configuration
Translate the hardware configuration and send it to controller.
56