Festo MSE6-E2M Operating Instruction page 47

Energy efficiency module
Table of Contents

Advertisement

Commissioning
DIL switch 2
DIL 2.1: ON
DIL 2.2: OFF
DIL 2.1: ON
DIL 2.2: ON
1) The status bits occupy 1 byte address space, 8 I bits
2) The I/O diagnostics interface occupies 4 bytes address space, 16 I and 16 O bits
Tab. 32: Setting diagnostic mode using DIL switch 2
Set IP addressing, DIL switch 3
DIL switches 3.1 ... 3.8 are used to set the type of addressing or the IP address of the energy efficiency
module.
DIL switch 3
DIL 3.1 ... 3.8: OFF
DIL 3.8: OFF 2
DIL 3.7: ON 2
DIL 3.6: OFF 2
DIL 3.5: ON 2
DIL 3.4: OFF 2
DIL 3.3: ON 2
DIL 3.2: ON 2
DIL 3.1: OFF 2
DIL 3.1 ... 3.8: ON
Tab. 33: Set IP addressing, DIL switch 3
Festo — MSE6-E2M — 2022-08d
Setting diagnostic mode
The 'I/O diagnostics interface' is switched on, + 2 bytes I/2 byte
2)
O
.
Reserved for future extensions.
Setting IP addressing
Dynamic/saved addressing.
All DIL switches in the OFF position, factory setting.
When switched on, the energy efficiency module receives a
dynamic or stored IP address via 'DHCP/BOOTP'.
7
= 128
Fixed addressing.
The host-ID of the IP address, 4th octet, is binary-coded with DIL
= 64
6
switch 3.1 ... 3.8. Permissible value range: 1 ... 254.
= 32
5
Example:
= 16
4
2
+ 2
+ 2
1
2
4
Set IP address: 192.168.1.86
= 8
3
= 4
2
= 2
1
0
= 1
Reset all IP parameters to factory settings.
All DIL switches in ON position.
All IP parameters of the energy efficiency module are reset to the
factory settings when device is switched on.
+ 2
= 2+ 4 + 16 + 64 = 86 host-ID
6
47