IBM System x iDataPlex dx360 M4 7912 Service Manual page 89

Problem determination
Table of Contents

Advertisement

800b0008-1301ffff
Redundancy
[RedundancySetElementName] has
been restored. (Power Unit)
Explanation: This message is for the use case when
an implementation has detected Redundancy was
Restored.
Internal Event: No
Severity: Info
Alert Category: Warning - Redundant Power Supply
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0561
SNMP Trap ID: 10
Automatically notify Support: No
User response: No action; information only.
800b0108-1301ffff
Redundancy Lost for
[RedundancySetElementName] has
asserted. (Power Unit)
Explanation: This message is for the use case when
Redundancy Lost has asserted.
Internal Event: No
Severity: Error
Alert Category: Critical - Redundant Power Supply
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 9
Automatically notify Support: No
User response:
1.
Check the LEDs for both power supplies.
2.
Follow the actions in Power-supply LEDs.
800b010a-1e81ffff
Redundancy Lost for
[RedundancySetElementName] has
asserted. (Cooling Zone)
Explanation: This message is for the use case when
Redundancy Lost has asserted.
Internal Event: No
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 11
Automatically notify Support: No
User response:
800b0008-1301ffff • 800b030c-2581ffff
1.
Make sure that the connectors on fan n are not
damaged.
2.
Make sure that the fan n connectors on the system
board are not damaged.
3.
Make sure that the fans are correctly installed.
4.
Reseat the fans.
5.
Replace the fans. (n = fan number)
800b010c-2581ffff
Redundancy Lost for
[RedundancySetElementName] has
asserted. (Backup Memory)
Explanation: This message is for the use case when
Redundancy Lost has asserted.
Internal Event: No
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 41
Automatically notify Support: No
User response:
1.
Check the system-event log for DIMM failure events
(uncorrectable or PFA) and correct the failures.
2.
Re-enable mirroring in the Setup utility.
800b030c-2581ffff
Non-redundant:Sufficient
Resources from Redundancy Degraded
or Fully Redundant for
[RedundancySetElementName] has
asserted. (Backup Memory)
Explanation: This message is for the use case when
a Redundancy Set has transitioned from Redundancy
Degraded or Fully Redundant to Non-
redundant:Sufficient.
Internal Event: No
Severity: Warning
Alert Category: Warning - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0806
SNMP Trap ID: 43
Automatically notify Support: No
User response:
1.
Check the system-event log for DIMM failure events
(uncorrectable or PFA) and correct the failures.
2.
Re-enable mirroring in the Setup utility.
71
Chapter 3. Diagnostics

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x idataplex dx360 m4 7913