806f0607-2584ffff
An SM BIOS Uncorrectable CPU
complex error for
[ProcessorElementName] has asserted.
(All CPUs)
Explanation: This message is for the use case when
an SM BIOS Uncorrectable CPU complex error has
asserted.
Internal Event: No
Severity: Error
Alert Category: Critical - CPU
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0816
SNMP Trap ID: 40
Automatically notify Support: No
User response:
1.
Update the latest level of system firmware and
device drivers are installed for all adapters and
standard devices, such as UEFI, IMM Ethernet,and
SAS. Important: Some cluster solutions require
specific code levels or coordinated code updates. If
the device is part of a cluster solution, verify that the
latest level of code is supported for the cluster
solution before you update the code.
2.
Run the DSA program.
3.
Reseat the adapter.
4.
Replace the adapter.
5.
(Trained technician only) Replace microprocessor
n. (n = microprocessor number)
6.
(Trained technician only) Replace the system
board.
One of the CPUs :
806f0608-1301ffff
[PowerSupplyElementName] has
a Configuration Mismatch. (PS
Configuration)
Explanation: This message is for the use case when
an implementation has detected a Power Supply with a
Configuration Error.
Internal Event: No
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0104
SNMP Trap ID: 4
Automatically notify Support: No
User response:
110
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
1.
Make sure that the power supplies installed are
with the same rating or wattage.
2.
Reinstall the power supplies with the same rating or
wattage.
806f070c-2001ffff
Configuration Error for
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 1)
Explanation: This message is for the use case when
an implementation has detected a Memory DIMM
configuration error has been corrected.
Internal Event: No
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0126
SNMP Trap ID: 41
Automatically notify Support: No
User response: Make sure that DIMMs are installed
and following the memory population chart in the
system publication.
806f070c-2002ffff
Configuration Error for
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 2)
Explanation: This message is for the use case when
an implementation has detected a Memory DIMM
configuration error has been corrected.
Internal Event: No
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0126
SNMP Trap ID: 41
Automatically notify Support: No
User response: Make sure that DIMMs are installed
and following the memory population chart in the
system publication.
806f070c-2003ffff
Configuration Error for
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 3)
Explanation: This message is for the use case when
an implementation has detected a Memory DIMM
configuration error has been corrected.

Advertisement